dc.contributor.author |
El Maarri, O. |
|
dc.contributor.author |
Luxembourg, B. |
|
dc.contributor.author |
Lindoff-Last, E. |
|
dc.contributor.author |
Khochhan, L. |
|
dc.contributor.author |
Bruhn, HD |
|
dc.contributor.author |
Delev, D. |
|
dc.contributor.author |
Watzaka, M. |
|
dc.contributor.author |
Seifried, E. |
|
dc.contributor.author |
Oldenburg, J. |
|
dc.date.accessioned |
2017-09-13T08:49:14Z |
|
dc.date.available |
2017-09-13T08:49:14Z |
|
dc.date.copyright |
2006 |
en_US |
dc.date.issued |
2017-09-13 |
|
dc.identifier.issn |
1592-8721 |
en_US |
dc.identifier.uri |
http://hdl.handle.net/10725/6177 |
|
dc.description.abstract |
The present study reports a method for the easy, rapid and cost effective detection of heterozygous large deletions. As a model gene all exons of the antithrombin gene were amplified in a one tube multiplex polymerase chain reaction (PCR) and the products separated according to their size by reverse-phase ion-pair high performance liquid chromatography. A significant reduction in the height of a peak in the probandOs sample compared to in the control indicates the presence of a large deletion of the corresponding allele. Using this approach we identified heterozygous deletions in four patients: the deletions affected exons 1 and 2, exon 7 and the whole antithrombin gene. |
en_US |
dc.language.iso |
en |
en_US |
dc.title |
Detection Of heterozygous large deletions in the antithrombin gene using multiplex polymerase chain reaction and denatured high performance liquid chromatography |
en_US |
dc.type |
Article |
en_US |
dc.description.version |
Published |
en_US |
dc.author.school |
SAS |
en_US |
dc.author.idnumber |
201508713 |
en_US |
dc.author.department |
Natural Sciences |
en_US |
dc.description.embargo |
N/A |
en_US |
dc.relation.journal |
Haematologica |
en_US |
dc.journal.volume |
91 |
en_US |
dc.journal.issue |
9 |
en_US |
dc.article.pages |
1264-1267 |
en_US |
dc.identifier.ctation |
Pavlova, A., El-Maarri, O., Luxembourg, B., Lindhoff-Last, E., Kochhan, L., Bruhn, H. D., ... & Oldenburg, J. (2006). Detection of heterozygous large deletions in the antithrombin gene using multiplex polymerase chain reaction and denatured high performance liquid chromatography. haematologica, 91(9), 1264-1267. |
en_US |
dc.author.email |
osman.elmaarri@lau.edu.lb |
en_US |
dc.identifier.tou |
http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php |
en_US |
dc.identifier.url |
http://www.haematologica.org/content/91/9/1264.full.pdf+html |
en_US |
dc.author.affiliation |
Lebanese American University |
en_US |