Abstract:
Background
Few patients have significant symptoms during wireless esophageal pH monitoring, and the capsule typically sloughs spontaneously. Severe discomfort during monitoring can occur that requires endoscopic dislodgement of the capsule.
Objective
To determine the frequency with which endoscopic capsule dislodgement is required and the outcomes of the intervention.
Design
Chart review.
Setting
University-based outpatient endoscopy facility.
Patients
A total of 452 consecutive patients undergoing wireless pH monitoring over a 3.5-year period.
Interventions
Endoscopic dislodgement of the capsule by using nudging with the endoscope tip and cold snare techniques.
Results
Eight subjects (1.8%) required endoscopic capsule dislodgement because of severe chest pain or odynophagia (n = 7) or severe foreign-body sensation (n = 1). Chest pain was the initial indication for pH monitoring in 5 (62.5%) of the subjects. Initial nudging with the endoscope tip successfully dislodged 2 capsules; continued nudging produced mucosal stripping in 3 subjects, which required hemostasis in 1. A cold snare was used successfully, without complication, to separate the capsule from stripped mucosa and as a primary removal method in the remainder of subjects. Capsule removal uniformly resulted in marked improvement of discomfort.
Conclusions
Endoscopic removal of the capsule was required in <2% of subjects who underwent wireless pH monitoring. Separation of the capsule from the mucosa with a cold snare may be the preferred method of accomplishing uncomplicated removal.
Citation:
Prakash, C., Jonnalagadda, S., Azar, R., & Clouse, R. E. (2006). Endoscopic removal of the wireless pH monitoring capsule in patients with severe discomfort. Gastrointestinal endoscopy, 64(5), 828-832.