High-throughput measurement of 25-hydroxyvitamin D by LC–MS/MS with separation of the C3-epimer interference for pediatric populations

LAUR Repository

Show simple item record

dc.contributor.author El-Khoury, Joe
dc.contributor.author Yang, Yifei
dc.contributor.author Rogers, Katherine
dc.contributor.author Wardle, Robert
dc.date.accessioned 2016-06-14T09:17:43Z
dc.date.available 2016-06-14T09:17:43Z
dc.date.copyright 2016 en_US
dc.date.issued 2016-06-14
dc.identifier.issn 0009-8981 en_US
dc.identifier.uri http://hdl.handle.net/10725/4031
dc.description.abstract Background Liquid chromatography–tandem mass spectrometry (LC–MS/MS) is widely used for the measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in blood. However, the presence of 25OHD3 C3-epimer (3-epi-25OHD3) may cause interference and overestimation of the 25OHD3 level. We developed a rapid and simple assay for measurement of 25OHD that separates this interference and to investigate its impact on 25OHD3 measurement in adult and pediatric populations. Methods Sample preparation consisted of protein precipitation followed by solid-phase extraction with an LC run time of 4.8 min. Method comparison with another LC–MS/MS method of a major reference laboratory that does not separate the C3-epimer interference was performed using adult (n = 52) and pediatric (n = 40) samples. Results This method is free from significant ion suppression, carryover and interference. The assay can separate 25OHD3 from the 3-epi-25OHD3, and can measure 25OHD2 and 25OHD3 from 4.2 to 310.7 ng/ml and 5.2 to 311.1 ng/ml, respectively. Method comparison with a LC–MS method that does not separate the interference revealed biases of − 0.15 and 4.54 for 25OHD3 measurement in adult and pediatric samples, respectively. Conclusion A fast and simple LC–MS/MS method for quantification of 25OHD3 and 25OHD2 without 3-epi-25OHD3 interference was developed. This assay is required for accurate quantitation of 25OHD3 in pediatric samples and suitable for routine use in a high volume clinical laboratory. en_US
dc.language.iso en en_US
dc.title High-throughput measurement of 25-hydroxyvitamin D by LC–MS/MS with separation of the C3-epimer interference for pediatric populations en_US
dc.type Article en_US
dc.description.version Published en_US
dc.author.school SOM en_US
dc.author.idnumber 201100951 en_US
dc.author.department N/A en_US
dc.description.embargo N/A en_US
dc.relation.journal Clinica Chimica Acta en_US
dc.journal.volume 454 en_US
dc.article.pages 102-106 en_US
dc.keywords Vitamin D en_US
dc.keywords Liquid chromatography en_US
dc.keywords Mass spectrometry en_US
dc.keywords C3-epimer en_US
dc.identifier.doi http://dx.doi.org/10.1016/j.cca.2016.01.004 en_US
dc.identifier.ctation Yang, Y., Rogers, K., Wardle, R., & El-Khoury, J. M. (2016). High-throughput measurement of 25-hydroxyvitamin D by LC–MS/MS with separation of the C3-epimer interference for pediatric populations. Clinica Chimica Acta, 454, 102-106. en_US
dc.author.email joe.el-khoury@lau.edu.lb en_US
dc.identifier.tou http://libraries.lau.edu.lb/research/laur/terms-of-use/articles.php en_US
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S000989811630002X en_US