.

Quantification of energy produced from an evacuated tube water heater in a real setting

LAUR Repository

Show simple item record

dc.contributor.author Houri, Ahmad
dc.contributor.author Salloum, Hussein
dc.contributor.author Ali, Anwar
dc.contributor.author Abdel Razek, Abdel Karim
dc.contributor.author Houri, Laila
dc.date.accessioned 2016-03-08T09:39:14Z
dc.date.available 2016-03-08T09:39:14Z
dc.date.copyright 2013
dc.date.issued 2016-03-08
dc.identifier.issn 0960-1481 en_US
dc.identifier.uri http://hdl.handle.net/10725/3298
dc.description.abstract For the first time, actual data regarding an evacuated tube SWH has been collected from an implemented system in Lebanon. The data collected was based on a number of sensors installed at various points in the system. The results indicated real hot water use of the household and operational temperatures throughout the year. The system provided more than 98% of the household needs indicating a clear over sizing of the system. Other findings include excessive heat generated in the summer, necessitating forced shadowing of the collectors. The system provided 3049 kWh/y and saved the family around $195. More significant savings are obtained by the electricity company since electricity in Lebanon is subsidized. This case study provides a reference point for the observed savings rather than estimated savings. en_US
dc.language.iso en en_US
dc.title Quantification of energy produced from an evacuated tube water heater in a real setting en_US
dc.type Article en_US
dc.description.version Published en_US
dc.author.school SAS en_US
dc.author.idnumber 199729070 en_US
dc.author.woa N/A en_US
dc.author.department Natural Sciences en_US
dc.description.embargo N/A en_US
dc.relation.journal Renewable Energy en_US
dc.journal.volume 49 en_US
dc.article.pages 111-114 en_US
dc.keywords Electricity en_US
dc.keywords Savings en_US
dc.keywords Consumption en_US
dc.keywords Financial en_US
dc.keywords Environmental en_US
dc.identifier.doi http://dx.doi.org/10.1016/j.renene.2012.01.052 en_US
dc.identifier.ctation Houri, A., Salloum, H., Ali, A., Razik, A. K. A., & Houri, L. (2013). Quantification of energy produced from an evacuated tube water heater in a real setting. Renewable energy, 49, 111-114. en_US
dc.author.email ahouri@lau.edu.lb
dc.identifier.url http://www.sciencedirect.com/science/article/pii/S0960148112000638


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search LAUR


Advanced Search

Browse

My Account