.

Stability Retrofit of Concrete Shear Walls Using Carbon Fiber Reinforced Polymers

LAUR Repository

Show simple item record

dc.contributor.author Al Sayegh, Houssam
dc.date.accessioned 2023-10-23T05:42:13Z
dc.date.available 2023-10-23T05:42:13Z
dc.date.copyright 2022 en_US
dc.date.issued 2023-01-24
dc.identifier.uri http://hdl.handle.net/10725/15114
dc.description.abstract Shear walls are key structural elements when it comes to resisting lateral loads in reinforced concrete buildings. Thus, they are exposed to extensive loading during earthquakes. Shear walls designed according to modern ACI provisions have demonstrated acceptable performance in the recent events such as Chile (2010) and New Zealand (2016) earthquakes. However, many old structures have shear walls that do not conform to modern building codes posing a threat to public safety in case of a seismic event. This research examines the seismic performance of slender, under-reinforced shear walls, and proposes retrofit guidelines to enhance the strength and ductility of this type of walls using carbon fiber reinforced polymers. Two full-scale shear walls were constructed with similar dimensions and material properties to shear walls in old buildings in Beirut, Lebanon. One of the walls was designated to be a control and tested as is, while the other was retrofitted using externally glued CFRP laminates with proper anchoring systems. The CFRP layout was designed to provide the missing confinement which is supplied by special boundary elements as per ACI section 18.10.6. The in-plane loading performance of the shear wall specimens was examined before and after the retrofit. Force deformation plots were produced for both tests and further specific in-plane and out-of-plane displacements were monitored using two high-performance cameras connected to a data acquisition software. Strain gauges were placed at different levels on the wall rebar to monitor their strain profile and yielding points. The results showed that the retrofitted wall had better performance than the control. Drift capacity was improved by 17% and longitudinal bar buckling was prevented. Moreover, it was observed that the control wall compression zone was completely crushed at 2.5% drift, whereas the retrofitted wall reached a drift of 3% with an intact concrete section. The CFRP laminates are shown to preserve the concrete core and retain the concrete chunks that crush and fall off during cyclic loading. The results of this study will aid in the development of a unified retrofit scheme to enhance the seismic performance of shear walls in old buildings, thus improving their safety in case of a seismic event. en_US
dc.language.iso en en_US
dc.subject Fiber-reinforced concrete en_US
dc.subject Carbon fibers -- Mechanical properties en_US
dc.subject Reinforced concrete construction en_US
dc.subject Polymeric composites -- Mechanical properties en_US
dc.subject Earthquake resistant design en_US
dc.subject Lebanese American University -- Dissertations en_US
dc.subject Dissertations, Academic en_US
dc.title Stability Retrofit of Concrete Shear Walls Using Carbon Fiber Reinforced Polymers en_US
dc.type Thesis en_US
dc.term.submitted Spring en_US
dc.author.degree MS in Civil And Environmental Engineering en_US
dc.author.school SOE en_US
dc.author.idnumber 201408644 en_US
dc.author.commembers Tabbara, Mazen
dc.author.commembers Ghannoum, Wassim
dc.author.department Civil Engineering en_US
dc.description.physdesc 1 online resource (xii, 53 leaves): col. ill. en_US
dc.author.advisor Abi Shdid, Caesar
dc.keywords Shear Wall en_US
dc.keywords Carbon Fiber-Reinforced Polymer en_US
dc.keywords Cyclic Loading en_US
dc.keywords Retrofit en_US
dc.keywords Confinement en_US
dc.keywords Boundary Element en_US
dc.keywords Out-of-Plane Buckling en_US
dc.keywords Compression Zone en_US
dc.description.bibliographiccitations Includes bibliographical references (leaves 51-53). en_US
dc.identifier.doi https://doi.org/10.26756/th.2023.599
dc.author.email houssam.sayegh@lau.edu.lb en_US
dc.identifier.tou http://libraries.lau.edu.lb/research/laur/terms-of-use/thesis.php en_US
dc.publisher.institution Lebanese American University en_US
dc.author.affiliation Lebanese American University en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search LAUR


Advanced Search

Browse

My Account